Test Report
No. CANEC1100056201  Date: 12 Jan 2011Page 1 of 5
DONGGUAN SHENG DA SOLDERING TIN PRODUCT FACTORY SHABU INDUSTRY ZONE,DALANG TOWN,DONGGUAN CITY CHINA
The following sample(s) was/were submitted and identified on behalf of the clients as :环保锡线
SGS Job No.
12927291 - GZ  :10.1
:SGS Internal Reference No.Date of Sample Received  :07 Jan 2011
Testing Period  :07 Jan 2011 - 12 Jan 2011
Test Requested  :Selected test(s) as requested by client. :Please refer to next page(s).Test Method Test Results  :Please refer to next page(s).
:
Conclusion
Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive 2002/95/EC and its subsequent amendments.
Signed for and on behalf of SGS-CSTC Ltd.
Silva Zhou
Approved Signatory
Test Report
No. CANEC1100056201  Date: 12 Jan 2011Page 2 of 5
Test Results:
:ID for specimen 1
CAN11-000562.001Silvery metal wire
:Description for specimen 1RoHS Directive 2002/95/EC MDL Limit Result Unit Test Method (Reference)Test Item(s)100Cadmium (Cd)/kg 2IEC 62321:2008, ICP-OES 1000Lead (Pb)16mg/kg 2IEC 62321:2008, ICP-OES 1000Mercury (Hg)
/kg 2IEC 62321:2008, ICP-OES #
Hexavalent Chromium (CrVI) by boiling water extraction Negative
-♢
IEC 62321:2008, UV-Vis
1000
Sum of PBBs
/kg --Monobromobiphenyl /kg 5IEC 62321:2008, GC-MS Dibromobiphenyl /kg 5IEC 62321:2008, GC-MS Tribromobiphenyl /kg 5IEC 62321:2008, GC-MS Tetrabromobiphenyl /kg 5IEC 62321:2008, GC-MS Pentabromobiphenyl /kg 5IEC 62321:2008, GC-MS Hexabromobiphenyl /kg 5IEC 62321:2008, GC-MS Heptabromobiphenyl /kg 5IEC 62321:2008, GC-MS Octabromobiphenyl /kg 5IEC 62321:2008, GC-MS Nonabromobiphenyl /kg 5IEC 62321:2008, GC-MS Decabromobiphenyl /kg 5IEC 62321:2008, GC-MS
1000
Sum of PBDEs
/kg --Monobromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Dibromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Tribromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Tetrabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Pentabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Hexabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Heptabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Octabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Nonabromodiphenyl ether /kg 5IEC 62321:2008, GC-MS Decabromodiphenyl ether
N.D.
mg/kg
5
IEC 62321:2008, GC-MS
sgs报告
Test Report No. CANEC1100056201  Date: 12 Jan 2011Page 3 of 5 Note:
1. mg/kg = ppm
2. N.D. = Not Detected (< MDL)
3. MDL = Method Detection Limit
4. ♢ = Spot-Test:
Negative = Absence of CrVI coating, Positive = Presence of CrVI coating;
(The tested sample should be further verified by boiling-water-extraction method if the spot test result is negative or cannot be confirmed.)
Boiling-water-extraction:
Negative = Absence of CrVI coating
Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm² sample surface area.
Storage conditions and production date of the tested sample are unavailable and thus results of Cr(VI) represent status of the sample at the time of testing.
5. # = Positive indicates the presence of CrVI on the tested areas.
Negative indicates the absence of CrVI on the tested areas.
6. "- " = Not regulated
Test Report No. CANEC1100056201  Date: 12 Jan 2011Page 4 of 5
Test Report No. CANEC1100056201  Date: 12 Jan 2011Page 5 of 5 Sample photo:
CANEC1100056201
CAN11-000562.001
SGS authenticate the photo on original report only
*** End of Report ***