工程图纸设计合同(工程设计合同范本大全)
工程图纸设计合同1
宜昌机场项目(中心变电站)工程图纸疑问
一、结构
1、 结施-1 :8.31)与结施-3 :71)中均明确独立基础(筏板基础)埋深有标高要求,基础均应砌筑在持力层顶面下不少于200mm处,独立基础埋深以标高控制还是以持力层控制?
回复:基础埋深为双控,基础挖至设计标高后,如已进入持力层顶面下不少于200mm,可停止开挖;否则需根据现场开挖情况经地勘认定土层,报至设计院。
2、结施-1: 8.3 2)独立基础与基础梁下应做防、隔水处理,设计图纸未明确防、隔水做法。
回复:目的防止基坑浸泡
3、结施-1:8.3 2) 与 结施-3: 72)独立基础两侧采用与垫层材料相同的材料回填,是采否用沙、碎石或C15砼回填,如果采用沙、碎石回填起不到防、隔水效果。
回复:地下室基础肥槽回填采用级配碎石分层碾压夯实回填,要求回填层的承载力特征值不小于180kPa, 压缩模量为10MPa。
4、结施-1: 8.5 1)中提到对基坑四周采取可靠的防护工程措施,保证临近建筑物的安全,基坑工程应由有资质的单位负责设计,本开闭所工程基坑开挖深度3M左右,设计应根据地勘报告及结合现场实际情况明确基坑支护形式,以便施工、监理有依据。
回复:需由有基坑支护单位确定
5、结施-1: 8.7地下室外墙水平施工缝两种做法,3mm厚钢板止水带或遇水膨胀止水条,建议采用3mm厚钢板止水带。楼板(梁)底面150-300mm处建议不设置施工缝,墙体与楼板(梁)砼一起浇筑。设计合同
回复:如能保证施工质量可取消,同意采用3mm厚钢板止水带
6、结施-3中QXTJ-1、2基础做法详图无配筋标注;墙下条基抗裂构造柱无配筋标注。
回复:QXTJ-1、2为无筋扩展基础,墙下条基抗裂构造柱如下:
7、本开闭所工程基础存在三种形式,筏板基础、独立基础及条形基础,且埋深不一,是否会存在不均匀沉降,引起墙体开裂。
回复:已满足计算要求
8、本开闭所工程基础设置在天然地基上,设计要求对地基进行钎探,但未明确钎探方案(钎探孔深及间距)。地基验槽要求设计及地勘到场。